Model M1
Optical model
Mirrors are not a number. They are a stripe of heat on a pipe. Move the tracker and watch the hot stripe walk off the tube. Geometric concentration only sizes the hole. The coating sees the map.
Optical efficiency
74.8%
26.92 kW on receiver
- Cg geometry
- 50×
- C_flux mean
- 37×
- C_flux peak
- 66×
- Peak / mean
- 1.77
- CPC intercept γ
- 85%
- IAM transverse
- 98%
- Block / shade
- 100%
- Spill
- 4.68 kW
Receiver-plane flux
Rows are transverse across the aperture. Columns run along the rail. A 50× pod is not 50 suns. Mean concentration here is η_opt × Cg.
q'' in kW/m²
8.6
8.6
8.6
8.6
8.6
8.6
8.6
8.6
31.2
31.2
31.2
31.2
31.2
31.2
31.2
31.2
59.5
59.5
59.5
59.5
59.5
59.5
59.5
59.5
49.7
49.7
49.7
49.7
49.7
49.7
49.7
49.7
19.2
19.2
19.2
19.2
19.2
19.2
19.2
19.2
33.6 kW/m²
Mean flux
59.5 kW/m²
Peak flux
50×
Cg
Geometry only
66×
C_flux peak
What the coating sees
Intercept vs tracking error
Other inputs held at the current settings. Past ~6–8 mrad the CPC starts to miss and peak-to-average climbs. That is G3, not a bigger mirror.
OP-C03
Optical budget sheet