Primary facets
Cheap area is the product. Silvered glass or polished aluminum, serviceable individually.
Pod: ~10 strips, 0.6 × 8 m. XP: four 1.0 × 0.50 m flats.
Bill of specialty
The field is cheap and sits there for decades. Almost everything interesting is a replaceable part on a frozen interface — or a catalogue instrument the lab cannot live without.
Two and a half acres. Pickup trucks of steel, tanker trucks of oil.
Cheap area is the product. Silvered glass or polished aluminum, serviceable individually.
Pod: ~10 strips, 0.6 × 8 m. XP: four 1.0 × 0.50 m flats.
Sets the optical geometry for decades. Repairable steel, not exotic alloy.
Low-profile LFR gantry, ~4 m receiver height. Dual-axis yoke on XP-C01.
Raises intercept without shrinking the aperture into an unverified ultra-flux hole.
Linear CPC over 100 mm illuminated width. Acceptance sized to tracking error.
Drawing OP-C02High-flux sunlight starts fires. Loss of tracking, flow, or over-temp must dump.
Hardware trip to dump/stow. Beam dump plate. Fence. No untracked focus over people.
Drawing OP-C02The wearing, upgradable part. Absorb and extract only.
400 × 180 × 160 mm, DN15 oil tubes, Pyromark control, QD stab plates.
Drawing RC-TThe oil sees the sun through a steel wall. Film temperature lives here. This is how light becomes a factory flange.
Two DN15 × 8 m. 250–390 °C oil. T_film ≈ T_bulk + q''_peak / h. Dump at 400 °C film.
Drawing RC-T02One tile can fail without retiring the field. Cartridge swap on a frozen optical datum.
Common header for a 10-pod cluster. Independent isolation per rail.
Drawing ST-C01This is the commercial wedge versus batteries-then-a-heater.
Hot ~390 °C / cold ~250 °C. Expansion tank, N2 blanket, drip pan, fire enclosure.
Drawing ST-C01Cg is geometry. Coatings and tubes see q''(x,y).
Swaps onto the 400 × 200 mm datum. Water-cooled pixels or Lambertian + camera.
Drawing XP-B03Gate G0 lives or dies on ṁ cp ΔT, not on a pretty coating.
1–4 L/min water (Phase A), matched RTDs, calibrated flowmeter, bypass, vent.
Drawing XP-B02Pin is the denominator of every efficiency. A 2% DNI error is a 2% lie.
First-class pyrheliometer on a separate tracker. Time-synced to the DAQ.
Drawing XP-B02G0 is a closure of a time window, not a screenshot.
1 Hz: DNI, flow, Tin, Tout, cavity T×4, ambient, wind. File hash on raw data.
Every receiver generation must land on the same plane. The field does not move.
Fixed pins and target plane on the rail. Tile swap without re-aligning facets.
Optional once convection at Class M is measured. Not in Phase A.
Only if G1 shows the window beats an open cavity after soiling and stress.
Electricity after G5. Never inside the tile.
Same heat header. Swap-in power block. Project survives if this never ships.